Remove deposits from the impeller and housing, clean the parts.
Check the axial clearance of the bearing with the shaft, especially if there is significant pump noise. The axial clearance should not exceed 0.13 mm at a load of 5 kgf.
Replace the oil seal with a new one.
Deformations and cracks on the pump housing and cover are not allowed.